Hybrid systems at low and high voltage

Grid, panels and batteries in one system that lowers the bill and feeds key loads during outages.

Low voltage LV (48 V)High voltage HV
Usually fitsHomes and villas with moderate backup loadsLarge villas and facilities with bigger loads and capacity
CurrentHigh, needing larger cables and protectionLower at the same power
SafetyLower touch voltage riskNeeds qualified technicians and dedicated isolation and safety means
CompatibilityWide options. Inverter to battery communication is checkedFollow the manufacturer compatibility list
In our calculator HV is suggested when current exceeds 200 A on a 48 V bus, or capacity exceeds 30 kWh. This is an estimating rule. The final decision belongs to an engineer after reviewing datasheets.

Questions that set the size

  • Which circuits must run during an outage? Do they include AC units?
  • How many backup hours do you actually need?
  • Will the battery cycle daily? Cycling uses battery life, so compare it against the night tariff.

Start with numbers

Enter consumption, loads and backup hours to see panel, inverter and battery capacity with a suggested voltage.

Hybrid calculator